Construction
Plain copper conductor according to IEC-60228 class 5
PVC insulated
Core identification : yellow green and black with imprinted numbers
Cores lay-up concentrically
Special PVC outer sheath
Additional 2 wires of galvanized steel embedded in sheath material on opposite sides of the cable
Application and Durability
Application : Use as a self supporting shaft cable. Usually installed on lift, cranes, control converters, high-bay racking system, cableway, etc.
Durability: • Improved resistance against low temperature
• High tensile support capability exceeding 1000N
• Resistance to UV radiation
Electrical and Technical Data
Working voltage Ue/U | : 300/500V |
Test voltage | : 1000 VAC/1 min |
Insulation Resistance | : 20 MΩ x Km |
Temperature Range | : - 300C to + 700C (Moved) |
: - 400C to + 700C (Unmoved) | |
Minimum Bending Radius | : 10 x cable diameter |
Cross section (mm2) | Outer Diameter approx (mm) | Cable Weight approx (kg/km) |
---|---|---|
12 x 1 | 14.9 / 24.6 | 387 |
18 x 1 | 16.8 / 27.2 | 524 |
25 x 1 | 20.2 / 30.6 | 690 |
8 x 1.5 | 13.7 / 24.1 | 382 |
12 x 1.5 | 16.7 / 27.1 | 505 |
16 x 1.5 | 18.6 / 29 | 626 |
20 x 1.5 | 20.9 / 31.3 | 772 |