GLASS FUSE

Home » Our Products » Fuses » Low Voltage » GLASS FUSE

5 x 20mm Fast-acting Glass Tube Fuses
GMA Series

Description

• Fast-acting, low breaking capacity
• Optional axial leads available
• 5 x 20mm physical size
• Glass tube, silver-plated (63mA-315mA) and nickel-
  plated (500mA-15A) brass endcap construction
• Designed to UL/CSA 248-14
• Ratings above 6.3A have a 0.8mm diameter lead
• With TR2 packaging code, lead wire length is 19.05mm

Agency Information

• UL Listed, Guide JDYX, File E19180, 63mA-6A
• UL Recognized, Guide JDYX2, File E19180, 7-15A
• CSA Certified, Class 1422-01, File 53787, 63mA-6A
• PSE Approval, 1A-15A

Ordering

• Specify packaging, product, and option code

Dimensions - mm

Electrical Characteristics
Rated Current% of Amp RatingOpening Time
63mA 100% None
63mA 135% 60 minutes maximum
63mA 200% 60 minutes maximum

Specifications
Product CodeAmp RatingVoltage Rating VacInterrupting Rating (amps)*Typical DC Cold Resistance (Ω)**Typical Pre-Arc I2t Vac†Maximum Voltage Drop (mV)‡
250Vac125Vac
GMA-63-R 63mA 250 35 10,000 15.750 0.00024 4700
GMA-100-R 100mA 250 35 10,000 7.840 0.0001 4300
GMA-125-R 125mA 250 35 10,000 4.895 0.0024 2600
GMA-200-R 200mA 250 35 10,000 2.500 0.001 3400
GMA-250-R 250mA 250 35 10,000 1.735 0.018 2200
GMA-300-R 300mA 250 35 10,000 0.906 0.019 470
GMA-315-R 315mA 250 35 10,000 0.839 0.019 450
GMA-500-R 500mA 250 35 10,000 0.454 0.15 230
GMA-600-R 600mA 250 35 10,000 0.256 0.32 200
GMA-750-R 750mA 250 35 10,000 0.186 0.47 200
GMA-800-R 800mA 250 35 10,000 0.170 0.70 180
GMA-1-R 1 250 35 10,000 0.163 0.48 300
GMA-1-25-R 1.25 250 100 10,000 0.122 0.84 290
GMA-1.5-R 1.5 250 100 10,000 0.090 1.6 270
GMA-1.6-R 1.6 250 100 10,000 0.080 2.0 260
GMA-2-R 2 125 100 10,000 0.066 3.1 250
GMA-2.5-R 2.5 125 100 10,000 0.046 4.9 240
GMA-3-R 3 125 100 10,000 0.039 8.8 215
GMA-3.15-R 3.15 125 - 10,000 0.036 9.7 210
GMA-3.5-R 3.5 125 - 10,000 0.030 13 210
GMA-4-R 4 125 - 10,000 0.026 19 205
GMA-5-R 5 125 - 10,000 0.021 29 200
GMA-6-R 6 125 - 10,000 0.017 45 180
GMA-7-R 7 125 - 200 0.012 150 110
GMA-8-R 8 125 - 200 0.009 280 110
GMA-10-R 10 125 - 200 0.006 280 110
GMA-15-R 15 125 - 150 0.004 950 100
* Interrupting ratings: Interrupting ratings for 63mA - 6A were measured at 70% - 80% power factor on AC. The interrupting ratings for 7A - 15A    were measured at 100% power factor on AC.
** DC Cold Resistance (Measured at <10% of="" rated="" current="" span="">
† Typical Pre-Arching I2t(I2t was measured at listed interrupting rating and rated voltage)
‡ Maximum Voltage drop (Voltage drop was measured at 20°C ambient temperature at rated current)
Time-Current Curve – GMA-R 63mA-800mA

Time-Current Curve – GMA-R 1-15A

Packaging Code
Packaging CodeDescription
BK 100 fuses packed into a cardboard carton
BK1 1000 fuses packed inti poly bag
TR2 1500 fuse packed into tape on a reel (19.05mm lead wire length)


Option Code
Option CodeDescription
V Axial lead-copper tinned wire with nickel-plated brass overcaps

 

Fast-Acting  1⁄4” x 1 1⁄4” Glass Tube Fuses
AGC Series

Description

• Fast-acting, low breaking capacity
• Optional axial leads available
• 1⁄4” x 1 1⁄4” (6.3 x 32mm) physical size
• Glass tube, nickel-plated brass endcap construction-
• UL Listed product meets standard 248-14

Agency Information 

• UL Listed Card: AGC 1⁄20-10 
• UL Recognition Card: AGC 11-40 
• CSA Component Acceptance Card (Class No. 1422 30) 
• CSA Certification Card (Class No. 1422 01)

Environmental Data
• Shock: 1⁄20 - 3⁄4A – MIL-STD-202, Method 213, Test Condition I; 1 - 30A –
  MIL-STD-202, Method 207, (HI Shock)
• Vibration: 1⁄20 - 30A – MIL-STD-202,Method 204, Test Condition A
  (Except 5g, 500Hz) 

Ordering
• Specify packaging code prefix, part number and option code suffix
  (if applicable)

Dimensions - mm


Specifications
Part NumberAc Voltage RatingInterrupting Rating (amps)*Typical DC Cold Resistance (Ω)**Typical Melting I2t ACTypical Voltage Drop
25012532
AGC-1/20-R 250 35 10,000 - 4500 0.00773 0.67
AGC-1/10-R 250 35 10,000 - 12.565 0.000787 6.00
AGC-1/8-R 250 35 10,000 - 6.800 0.00131 4.67
AGC-3/16-R 250 35 10,000 - 4.900 0.00637 4.12
AGC-2/10-R 250 35 10,000 - 3.360 0.00435 4.51
AGC-1/4-R 250 35 10,000 - 2.300 0.0148 0.89
AGC-3/10-R 250 35 10,000 - 1.670 0.0208 2.88
AGC-3/8-R 250 35 10,000 - 1.203 0.0321 4.59
AGC-1/2-R 250 35 10,000 - 0.615 0.269 0.59
AGC-3/4-R 250 35 10,000 - 0.312 0.851 0.37
AGC-1-R 250 35 10,000 - 0.190 1.615 0.31
AGC-1-1/4-R 250 100 10,000 - 0.145 0.018 0.35
AGC-1-1/2-R 250 100 10,000 - 0.115 0.0149 0.27
AGC-2-R 250 100 10,000 - 0.078 0.00509 0.28
AGC-2-1/4-R 250 100 10,000 - 0.067 0.00588 0.26
AGC-2-1/2-R 250 100 10,000 - 0.057 0.00879 0.31
AGC-3-R 250 100 10,000 - 0.045 0.0167 0.25
AGC-4-R 250 200 10,000 - 0.030 0.0305 0.22
AGC-5-R 250 200 10,000 - 0.024 0.045 0.23
AGC-6-R 250 200 10,000 - 0.020 0.071 0.23
AGC-7-R 250 200 10,000 - 0.017 0.105 0.23
AGC-7-1/2-R 250 200 10,000 - 0.0146 - -
AGC-8-R 250 200 10,000 - 0.014 0.152 0.19
AGC-9-R 250 200 10,000 - 0.012 0.21 0.18
AGC-10-R 250 200 10,000 - 0.008 0.492 0.20
AGC-12-R 32 - - 1000 0.0070 - -
AGC-14-R 32 - - 1000 0.0062 - -
AGC-15-R 32 - - 1000 0.006 0.566 0.14
AGC-20-R 32 - - 1000 0.004 1.438 0.12
AGC-25-R 32 - - 1000 0.003 2.109 0.11
AGC-30-R 32 - - 1000 0.002 3.807 0.12
AGC-35-R 32 - - 1000 0.0014 - -
AGC-40-R 32 - - 1000 0.0019 - -

* DC Cold Resistance (Measured at ≤10% of rated current)
† Typical Melting I2t (A2Sec) (I2t was measured at listed interrupting rating and rated voltage.)
‡ Typical Voltage Drop (Voltage drop was measured at 25°C ambient temperature at rated current) 

 

Packaging Code Prefix
CodeDescription
BK 100 pieces of fuses packed into a cardboard carton with flaps folded
BK1 1000 pieces of fuses packed into a cardboard carton with flaps folded

Option Code Suffix
CodeDescription
B Board Washable-hermetically sealed to withstand aqueous cleaning
V Axial lead-copper tinned wire with nickel-plated brass overcaps
-R RoHS Compliant



5 x 20mm Medium Time-Delay Glass Tube Fuses
GMC Series

Description
• Medium time-delay, low breaking capacity
• Available with optional axial leads
• 5 x 20mm physical size
• Glass tube, nickel-plated brass endcap construction
• Designed to UL/CSA 248-14

Agency Information
• UL Listed, Guide JDYX, File E19180, 63mA-6.3A
• UL Recognized Card: (7A-10A) Guide JDYX2, File E19180
• CSA Certified, Class 1422-01, File E65063, 63mA-6.3A
• MITI Approval, 1A-10A
• KC-Mark: Certificate SU05011-4001 (63mA~250mA); SU05011-4002
  (300mA~800mA); SU05011-4003 (1A~3.15A); SU05011-4004 (3.5A~6.3A)

Ordering
• Specify packaging code prefix, product number and option code suffix
• For RoHS compliant version (suffix “-R”), drop mA or A from product code
  (e.g., GMC-2-R)

Dimensions - mm

• Ratings above 6.3A have a 0.8mm diameter lead
• With TR2 packaging code, lead wire length is 19.05mm
 
Electrical Characteristics
Rated Current% of Amp RatingOpening Time
63mA-10A 100% None
63mA-10A 135% 60 minutes maximum
63mA-10A 200% 2 minutes maximum

Specifications
Product CodeVoltage Rating VacInterrupting Rating (amps)*Typical DC Cold Resistance (Ω)**Typical Pre-Arc I2t AC†Maximum Voltage Drop (mV)‡
250Vac125Vac
GMC-63mA 250 35 10,000 10.350 0.0027 1400
GMC-80mA 250 35 10,000 - 0.0050 1400
GMC-100mA 250 35 10,000 4.775 0.0094 1200
GMC-125mA 250 35 10,000 3.400 0.014 1000
GMC-150mA 250 35 10,000 2.555 0.022 800
GMC-160mA 250 35 10,000 2.295 0.022 730
GMC-200mA 250 35 10,000 1.395 0.032 650
GMC-250mA 250 35 10,000 0.965 0.046 490
GMC-300mA 250 35 10,000 0.828 0.081 580
GMC-315mA 250 35 10,000 0.685 0.081 480
GMC-400mA 250 35 10,000 0.615 0.18 510
GMC-500mA 250 35 10,000 0.335 0.41 370
GMC-600mA 250 35 10,000 0.282 0.60 360
GMC-630mA 250 35 10,000 0.246 0.66 360
GMC-700mA 250 35 10,000 0.213 0.85 340
GMC-750mA 250 35 10,000 0.213 0.85 320
GMC-800mA 250 35 10,000 0.180 0.85 290
GMC-1A 250 35 10,000 0.156 1.8 250
GMC-1.25A 250 100 10,000 0.098 3.4 200
GMC-1.5A 250 100 10,000 0.076 5.4 190
GMC-1.6A 250 100 10,000 0.067 5.8 160
GMC-2A 250 100 10,000 0.043 8.9 130
GMC-2.5A 250 100 10,000 0.035 13 130
GMC-3A 250 100 10,000 0.026 19 130
GMC-3.15A 250 100 10,000 0.025 23 130
GMC-3.5A 125 - 10,000 0.022 25 130
GMC-4A 125 - 10,000 0.019 36 120
GMC-5A 125 - 10,000 0.014 58 120
GMC-6A 125 - 10,000 0.013 88 120
GMC-6.3A 125 - 10,000 0.012 110 120
GMC-7A 125 - 200 0.012 150 120
GMC-8A 125 - 200 0.009 200 110
GMC-10A 125 - 200 0.007 300 110
* Interrupting ratings: Interrupting ratings for 63mA - 6.3A were measured at 70% - 80% power factor on AC. The interrupting ratings for 7A - 10A were measured at 100% power factor on AC.
** DC Cold Resistance (Measured at <10% of="" rated="" current="" span="">
† Typical Pre-Arching I2t (I2t was measured at listed interrupting rating and rated voltage)
‡ Maximum Voltage drop (Voltage drop was measured at 20°C ambient temperature at rated current)


Packaging Code
Product Number PrefixDescription
BK- 100 fuses packed into a cardboard carton
BK1 1000 fuses packed inti poly bag
TR2 1500 Axial lead fuses packed into tape on a reel (19.05mm lead wire length)


Option Code
Product Number PrefixDescription
-V Axial lead-copper tinned wire with nickel-plated brass overcaps (place before amp rating; e.g.,GMC-V-2)
-R RoHS Compliant version (drop "mA or "A" from product number



1/4˝ x 1 1/4˝  Time-Delay, Glass Tube Fuses
MDL Series

Description
• Time-delay
• Optional axial leads available
• 1 ⁄4 x 1 1⁄4 (6.4 x 31.7mm) physical size
• Glass tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14

Agency Information
• UL Listed Card: MDL 1/16 - 8A (Guide JDYX, File E19180)
• UL Recognized Card: MDL 9 - 30A (Guide JDYX2, 
  File E19180)
• CSA Certification Card: MDL 1/16 - 8A (Class No. 1422-01)
• CSA Component Acceptance: MDL 9-30A
 (Class No. 1422-30)
• CE

Environmental Data
• Shock: 1A thru 30A – MIL-STD-202, Method 207, (HI Shock)
• Vibration: 1/4A thru 30A – MIL-STD-202, Method 204, Test
  Condition C (Except 5g, 500HZ)

Ordering
Specify packaging code
• Insert packaging code prefix before part number. E.g., BK 
  (or BK1)-MDL-5-R
Specify option codes if desired
• For axial leads, insert “V” between catalog series and amp 
  rating. E.g., BK-MDL-V-5-R
• For board washable, insert “B” between catalog series and
  amp rating. E.g., BK-MDL-B-5-R
• For axial leads and board washable, insert “B” then “V”
  between catalog series and amp rating. E.g., BK-MDL-BV-5-R

Dimensions - mm (in)
 
 
Electrical Characteristics
Rated Current% of Amp RatingOpening Time
1/16-30A 100% None
1/16-30A 135% 60 minutes maximum
1/16-30A 200% 120 second maximum
1/16-3A 200% 5 second miniimum
3-2/10-8A 200% 12 second miniimum

Specifications
Part NumberAc Voltage RatingInterrupting Rating (amps)*Typical DC Cold Resistance (Ω)**Typical Melting I2t ACTypical Voltage Drop
250Vac125Vac32Vac
MDL-1/6-R 250 35 10,000 - 45.6 0.0046 2.79
MDL-1/10-R 250 35 10,000 - 15.68 0.0420 1.95
MDL-1/8-R 250 35 10,000 - 12.238 0.0422 1.52
MDL-3/16-R 250 35 10,000 - 4.81 0.116 1.05
MDL-2/10-R 250 35 10,000 - 5.234 0.314 0.972
MDL-1/4-R 250 35 10,000 - 3.208 0.447 0.965
MDL-3/10-R 250 35 10,000 - 2.046 0.412 0.808
MDL-3/8-R 250 35 10,000 - 1.567 0.982 1.46
MDL-1/2-R 250 35 10,000 - 0.943 1.656 1.27
MDL-3/4-R 250 35 10,000 - 0.397 4.343 1.01
MDL-1-R 250 35 10,000 - 0.273 11.498 0.995
MDL-1-1/4-R 250 100 10,000 - 0.205 86.2 0.722
MDL-1-1/2-R 250 100 10,000 - 0.156 22.7 0.721
MDL-2-R 250 100 10,000 - 0.116 62.3 0.644
MDL-2-1/4-R 250 100 10,000 - 0.096 49.6 0.535
MDL-2-1/2-R 250 100 10,000 - 0.081 63.1 0.410
MDL-3-R 250 100 10,000 - 0.057 67.5 0.345
MDL-4-R 250 200 10,000 - 0.038 19.3 0.187
MDL-5-R 250 200 10,000 - 0.025 32.0 0.160
MDL-6-R 250 200 10,000 - 0.022 37.4 0.155
MDL-6-1/4-R 250 200 10,000 - 0.02 38.7 0.152
MDL-7-R 250 200 10,000 - 0.018 42.7 0.140
MDL-8-R 250 200 10,000 - 0.015 47.8 0.119
MDL-9-R 32 - - 1000 0.012 51.5 0.124
MDL-10-R 32 - - 1000 0.01 64.4 0.114
MDL-15-R 32 - - 1000 0.005 354.0 0.130
MDL-20-R 32 - - 1000 0.004 2914.0 0.530
MDL-25-R 32 - - 1000 0.01225 15221.0 0.30
MDL-30-R 32 - - 1000 0.0011 15581.0 0.40
* Interrupting Ratings (Interrupting ratings were measured at 70% - 80% power factor on AC)
** DC Cold Resistance (Measured at ≤10% of rated current)
† Typical Melting I2t (A2Sec) (I2t was measured at listed interrupting rating and rated voltage.)
‡ Typical Voltage Drop (Voltage drop was measured at 25°C±3°C ambient temperature at rated current)