Bussmann series
500 Volts gG/gL NH Fuse links
Product description
Eaton’s Bussmann series 500 Volts NH square
bodied industrial fuse links are suitable for a
wide variety of applications.
Standard features
Product description
Eaton’s Bussmann series 500 Volts NH square
bodied industrial fuse links are suitable for a
wide variety of applications.
Standard features
• Reliable dual indicator system
• Low temperature rise
• Globally compliant
• Compatible with Bussmann series PV NH
base range (see data sheet 10163)
Catalogue symbol:
• (amp)NHG(size)B
Fuse holders (ordered separately)
Catalogue symbol:
• (amp)NHG(size)B
Fuse holders (ordered separately)
• Fuse bases
• DIN-Rail mounting and screw mounting:
1-pole SD(size)-D, 3-pole TD(size)-D
• Screw mounting only: SD(size)-S
• Fuse rails - vertical: BFR Series
• Fuse switch disconnectors vertical: BFD Series
• Fuse switch disconnectors horizontal: BFH Series
Fuse size:
Fuse size:
• 000 to 4
Technical data:
• Volts: 500 V a.c.
• Amps: 2 to 1250 A
• Breaking capacity: 120 kA AC
• Operating frequency: 45-62 Hz
• Class of operation: gG/gL
Standards/Approvals:
• IEC 60269
• VDE 0636
• DIN 43620
• CE
Microswitches:
• 170H0236
• BVL50
Size - mm
Size - mm
Size | a1 | a2 | a3 | a4 | b | c1 | c2 | d | e1 | e2 | e3 | e4 | f |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
(max) | (max) | (max) | (max) | ||||||||||
000 | 78.5 ± 1.5 | 54 | 45 ± 1.5 | 49 ± 1.5 | 15 | 35 | 10 | 2 ± 0.5 | 41 | 21 | 16 | 6 | 8 |
00 | 78.5 ± 1.5 | 54 | 45 ± 1.5 | 49 ± 1.5 | 15 | 35 | 11 | 2 ± 0.5 | 48 | 30 | 25 | 6 | 15 |
0 | 125 ± 2.5 | 68 | 62 | 68 | 15 | 35 | 11 | 2.5 ± 0.5 | 48 | 30 | 25 | 6 | 15 |
01 | 135 ± 2.5 | 75 | 62 ± 2.5 | 68 ± 2.5 | 15 | 40 | 11 | 2.5 ± 0.5 | 48 | 30 | 25 | 6 | 15 |
1 | 135 ± 2.5 | 75 | 62 ± 2.5 | 68 ± 2.5 | 20 | 40 | 11 | 2.5 ± 0.5 | 53 | 40 | 25 | 6 | 15 |
02 | 150 ± 2.5 | 75 | 62 ± 2.5 | 68 ± 2.5 | 20 | 48 | 11 | 2.5 ± 0.5 | 53 | 40 | 25 | 6 | 15 |
2 | 150 ± 2.5 | 75 | 62 ± 2.5 | 68 ± 2.5 | 25 | 48 | 11 | 2.5 ± 0.5 | 61 | 53 | 25 | 6 | 15 |
03 | 150 ± 2.5 | 75 | 62 ± 2.5 | 68 ± 2.5 | 25 | 60 | 11 | 2.5 ± 0.5 | 61 | 53 | 25 | 6 | 15 |
3 | 150 ± 2.5 | 75 | 62 ± 2.5 | 68 ± 2.5 | 32 | 60 | 11 | 3 ± 0.5 | 75 | 70 | 25 | 6 | 18 |
4 | 200 ± 3 | 84 | 62 ± 2.5 | 90 ±3 | 50 | 85 | 10 | 3 ± 0.5 | 102 | 87 | 25 | 8 | 30 |
Tabel 2. Part numbers sizes 000 to 01
Size | Rated current | Rated voltage | gG/gL dual indicator | |
---|---|---|---|---|
(Amps) | (V a.c.) | Voltage conducting metal gripping lugs | Insulated metal gripping lugs | |
000 | 2 | 500 | 2NHG000B | 2NHG000BI |
000 | 4 | 4NHG000B | 4NHG000BI | |
000 | 6 | 6NHG000B | 6NHG000BI | |
000 | 10 | 10NHG000B | 10NHG000BI | |
000 | 16 | 16NHG000B | 16NHG000BI | |
000 | 20 | 20NHG000B | 20NHG000BI | |
000 | 25 | 25NHG000B | 25NHG000BI | |
000 | 32 | 32NHG000B | 32NHG000BI | |
000 | 35 | 35NHG000B | 35NHG000BI | |
000 | 40 | 40NHG000B | 40NHG000BI | |
000 | 50 | 50NHG000B | 50NHG000BI | |
000 | 63 | 63NHG000B | 63NHG000BI | |
000 | 80 | 80NHG000B | 80NHG000BI | |
000 | 100 | 100NHG000B | 100NHG000BI | |
00 | 50 | 50NHG00B | 50NHG00BI* | |
00 | 63 | 63NHG00B | 63NHG00BI* | |
00 | 80 | 80NHG00B | 80NHG00BI* | |
00 | 100 | 100NHG00B | 100NHG00BI* | |
00 | 125 | 125NHG00B | 125NHG00BI | |
00 | 160 | 160NHG00B | 160NHG00BI | |
0 | 6 | 6NHG0B | ||
0 | 10 | 10NHG0B | ||
0 | 16 | 16NHG0B | ||
0 | 20 | 20NHG0B | ||
0 | 25 | 625NHG0B | ||
0 | 32 | 32NHG0B | ||
0 | 35 | 35NHG0B | ||
0 | 40 | 40NHG0B | ||
0 | 50 | 50NHG0B | ||
0 | 63 | 63NHG0B | ||
0 | 80 | 80NHG0B | ||
0 | 100 | 100NHG0B | ||
0 | 125 | 125NHG0B | ||
0 | 160 | 160NHG0B | ||
01 | 6 | 6NHG01B | 6NHG01BI | |
01 | 10 | 10NHG01B | 10NHG01BI | |
01 | 16 | 16NHG01B | 16NHG01BI | |
01 | 20 | 20NHG01B | 20NHG01BI | |
01 | 25 | 25NHG01B | 25NHG01BI | |
01 | 32 | 32NHG01B | 32NHG01BI | |
01 | 35 | 35NHG01B | 35NHG01BI | |
01 | 40 | 40NHG01B | 40NHG01BI | |
01 | 50 | 50NHG01B | 50NHG01BI | |
01 | 63 | 63NHG01B | 63NHG01BI | |
01 | 80 | 80NHG01B | 80NHG01BI | |
01 | 100 | 100NHG01B | 100NHG01BI | |
01 | 125 | 125NHG01B | 125NHG01BI | |
01 | 160 | 160NHG01B | 160NHG01BI |
Tabel 3. Part numbers sizes 1 to 4
Size | Rated current | Rated voltage | gG/gL dual indicator | |
---|---|---|---|---|
(Amps) | (V a.c.) | Voltage conducting metal gripping lugs | Insulated metal gripping lugs | |
1 | 50 | 500 | 50NHG1B | 50NHG1BI* |
1 | 63 | 500 | 63NHG1B | 63NHG1BI* |
1 | 80 | 500 | 80NHG1B | 80NHG1BI* |
1 | 100 | 500 | 100NHG1B | 100NHG1BI* |
1 | 125 | 500 | 125NHG1B | 125NHG1BI* |
1 | 160 | 500 | 160NHG1B | 160NHG1BI* |
1 | 200 | 500 | 200NHG1B | 200NHG1BI* |
1 | 224 | 500 | 224NHG1B | 224NHG1BI* |
1 | 250 | 500 | 250NHG1B | 250NHG1BI* |
1 | 315 | 440 | 315NHG1B | 315NHG1BI* |
1 | 355 | 440 | 355NHG1B | 355NHG1BI* |
02 | 35 | 500 | 35NHG02B | 35NHG02BI |
02 | 40 | 500 | 40NHG02B | 40NHG02BI |
02 | 50 | 500 | 50NHG02B | 50NHG02BI |
02 | 63 | 500 | 63NHG02B | 63NHG02BI |
02 | 80 | 500 | 80NHG02B | 80NHG02BI |
02 | 100 | 500 | 100NHG02B | 100NHG02BI |
02 | 125 | 500 | 125NHG02B | 125NHG02BI |
02 | 160 | 500 | 160NHG02B | 160NHG02BI |
02 | 200 | 500 | 200NHG02B | 200NHG02BI |
02 | 224 | 500 | 224NHG02B | 224NHG02BI |
02 | 250 | 500 | 250NHG02B | 250NHG02BI |
2 | 250 | 500 | 250NHG2B | 250NHG2BI* |
2 | 300 | 500 | 300NHG2B | 300NHG2BI* |
2 | 315 | 500 | 315NHG2B | 315NHG2BI |
2 | 355 | 500 | 355NHG2B | 355NHG2BI |
2 | 400 | 500 | 400NHG2B | 400NHG2BI |
2 | 425 | 500 | 425NHG2B | 425NHG2BI* |
2 | 450 | 500 | 450NHG2B | 450NHG2BI* |
2 | 500 | 440 | 500NHG2B | 500NHG2BI* |
03 | 250 | 500 | 250NHG03B | 250NHG03BI |
03 | 315 | 500 | 315NHG03B | 315NHG03BI |
03 | 355 | 500 | 355NHG03B | 355NHG03BI |
03 | 400 | 500 | 400NHG03B | 400NHG03BI |
3 | 315 | 500 | 315NHG3B | |
3 | 355 | 500 | 355NHG3B | |
3 | 400 | 500 | 400NHG3B | |
3 | 425 | 500 | 425NHG3B | |
3 | 500 | 500 | 500NHG3B | |
3 | 630 | 500 | 630NHG3B | |
3 | 800 | 440 | 800NHG3B | |
4** | 500 | 500 | 500NHG4G | |
4** | 630 | 500 | 630NHG4G | |
4** | 800 | 500 | 800NHG4G | |
4** | 1000 | 500 | 1000NHG4G | |
4** | 1250 | 500 | 1250NHG4G |
* Available upon request
** Single indicator and slotted end tags